IFOS-6 series
Inertial measurement units
- Angular rate range, °/s
- ±290
- Bias drift at fixed temperature, °/h
- ≤0.02
- ARW, °/√h
- ≤0.002 – ≤0.005
- VRW, µg/√Hz
- ≤20 – ≤60

Specifications
| Parameter | IFOS-6M-G* | IFOS-6 | IFOS-6A-G* |
|---|---|---|---|
| Gyro | |||
| Range of measured angular rate, °/s | ±290 | ±290 (optional ±1000) | ±290 |
| Bias drift at fixed temperature, °/hour | ≤0.02 | ≤0.02 | ≤0.02 |
| Bias drift at changing temperature from -30°C to +60°C (100s-averaging, 1σ), °/hour | ≤0.05 | ≤0.05 | ≤0.05 |
| Scale factor error in temperature range -30°C to +60°C (1σ), ppm | ≤200 | ≤100 | ≤200 |
| Random walk, °/√hour | ≤0.002 | ≤0.005 | ≤0.002 |
| Bandwidth, Hz | >1000 (user defined) | >1000 (user defined) | >1000 (user defined) |
| Accelerometers | |||
| Accelerometer type | MEMS | Quartz | Quartz |
| Range of measured acceleration, g | ±10g to ±40g | ±10g to ±60g | ±10g to ±60g |
| Bias drift at constant temperature, mg | ≤0.03 | ≤0.02 | ≤0.02 |
| Bias drift in temperature range: -30°C to +60°C (3σ), mg | 0.3 | 0.25 | 0.25 |
| Velocity random walk, µg/√Hz | ≤60 | ≤20 | ≤20 |
| Scale factor error in temperature range -30°C to +60°C (3σ), ppm | ≤100 | ≤200 | ≤200 |
| Physical Characteristics | |||
| Misalignment, ° | ≤0.06 | ≤0.06 | ≤0.06 |
| Output sample rate | up to 2000 Hz | up to 2000 Hz | up to 2000 Hz |
| Power supply, V | 5±0.25 | 27±5 | 5±0.25 |
| Power consumption, W | ≤8 W | ≤20 W | ≤8 W |
| Digital output interface | RS-422 | RS-422 | RS-422 |
| Operation temperature | -30°C ~ +60°C | -30°C ~ +60°C | -30°C ~ +60°C |
| Dimensions, mm | 123 x 123 x 100 | 140 × 140 × 110 | 123 x 123 x 100 |
| Weight, kg | 1.7 | 3 | 1.7 |
* with 3-fiber SLED transceiver
Charts
Need a quotation or a specification for your application?
Request a quoteProducts are dual-use items; export from the EU requires authorisation. Export control